Update Lab 1 is imminent
we noticed a problem in task 1 as we are not after a V/I curve but a V/V curve: the 2-wire V/I analyzer won't work for that. So we'll have to do it using the function genrator providing a triangular wave or saw-tooth wave and observing both input and output to the opamp with the oscilloscope. You'll also need to use a resistive divider to make the function generator have good resolution...
I'll write an update of the Lab 1 task 1 later today, being more specific, but you may also ask Henrik in the lab today.